PUBLICATIONS LIST- Paul D. Levine

    1. Levine, N.H. Anger, K.B. Jaeger, B.E. Mellons, "Intrinsic Temperature
    Standards Below 90 K", in Proc. National Conference of Standards Laboratories
    Workshop and Symposium, sec 42, pp 1-19, 1987

    2. Levine, N.H. Anger, K.B. Jaeger, B.E. Mellons, "Cryogen Free System for the
    Realization of Triple Points Below 90 K", in Proc. IEEE Instrumentation and
    Measurement Technology Conf., pp 116-25, 1988

    3. Turneaure, E.A. Cornell, P.D. Levine, J.A. Lipa "The Stanford Relativity
    Gyroscope Experiment: Ultrahigh Vacuum Techniques for the Experiment" in NEAR
    ZERO:NEW FRONTIERS OF PHYSICS, edited by J.D. Fairbank, B.S. Deaver, C.W.F.
    Everitt and P.E. Michelson (W.H. Freeman and Co., New York, 1988) pp 671-8.

    4. Levine, B.E. Mellons "Development of a Pyrometer Calibration Station for
    Temperatures from 800 to 2300 Deg C", in Proc. Measurement Science Conf., sec
    4D, pp 26-39, 1989

    5. Levine, K.B. Jaeger, B.E. Mellons, "Precision AC Measurements of Temperature
    Below 90 K", IEEE Transactions on Instrumentation and Measurement, Vol. 38 pp
    428-33, (April 1989)

    6. Levine, B.E. Mellons, "Evaluation of the Gallium Melting Point by a Two Cell
    Intercomparison", in Proc. National Conference of Standards Laboratories
    Workshop and Symposium, pp 541-52, (Aug. 1990)

    7. Jaeger, P.D. Levine, C.A. Zack, "Industrial Experience with the Quantum Hall
    Effect" IEEE Transactions on Instrumentation and Measurement, Vol. 40 pp 256-
    61 (April 1991)

    8. Levine, B.E. Mellons, W. Schneider, "Industrial Experience with the Primary
    Calibration of High Temperature Platinum Resistance Thermometers"
    , "Temperature:
    Its Measurement and Control In Science and Industry", Vol 6 pp 1073-75, 1992

    9. Levine, B.E. Mellons, W. Schneider, "Development of a Stand-Alone Calibration
    System for Long Stem SPRTs"
    , "Temperature: Its Measurement and Control In
    Science and Industry", Vol 6 pp 405-8, 1992

    10. Levine, B.E. Mellons"Cryogenic Thermometer Calibration System Based on
    Triple Points from D2 to H20"
    , "Temperature: Its Measurement and Control In
    Science and Industry", Vol 6 pp 1067 9, 1992

    11. Levine, P. Metz, J. Zugel "Recommended Intrinsic Standards Practice (RISP-
    2): Water Triple Point Cell", National Conference of Standards Laboratories, Aug
    1992

    12. Levine, J.R. Sweda "Development of a Primary Standard Ultra-High Vacuum
    Calibration Station", J. Vac. Sci. and Technol. A 12(4), pp 1727, July/Aug 1994

    13. Levine, J.R. Sweda "A Primary Standard High Vacuum Calibration Station for
    Industrial Applications"
    , J. Vac. Sci. and Technol. A 14(3), PP 1297-1302,
    May/June 1996

    14. Levine, J.R. Sweda "A Precision Gas Flowmeter For Vacuum Calibration", J.
    Vac. Sci. and Technol. A 15(3) May/June 1997; pp 747-752

    15. Levine, P.D. "A New Approach to Gas Flow Calibration", Measurement;43(2010) pp. 1644-1648 Please contact Zero K Designs directly for a preprint of this paper.